Stainless Steel Pipe Schedule Chart: 4 Key Sizes Explained

Contents

A stainless steel pipe schedule chart connects a nominal pipe size to its outside diameter and nominal wall thickness. Start with NPS, find the outside diameter, then read across to the specified schedule. The schedule number alone does not tell you the wall thickness.

For example, NPS 2 stainless steel pipe has an outside diameter of 60.33 mm in the reference chart below. Its nominal wall is 2.77 mm at Schedule 10S, 3.91 mm at 40S, and 5.54 mm at 80S. The outside stays the same; the bore becomes smaller as the wall gets thicker.

Stainless steel round pipes stacked on warehouse racks

Key takeaways

  • NPS and DN are nominal size designations. Use the OD column for the physical outside dimension.
  • Read schedule together with pipe size and the dimensional standard.
  • Schedule describes a dimensional series; pressure suitability needs a separate engineering check.
  • Specify grade, manufacturing route and inspection requirements separately from dimensions.

Stainless steel pipe schedule chart in millimetres

The selected sizes below reproduce nominal dimensions from InfraBuild’s October 2022 pipe reference, page 18. All four schedule columns show wall thickness in millimetres. This is a purchasing reference, not a complete standard or a tolerance table.

NPS DN OD mm 5S wall 10S wall 40S wall 80S wall
½ 15 21.34 1.65 2.11 2.77 3.73
¾ 20 26.67 1.65 2.11 2.87 3.91
1 25 33.40 1.65 2.77 3.38 4.55
1¼ 32 42.16 1.65 2.77 3.56 4.85
1½ 40 48.26 1.65 2.77 3.68 5.08
2 50 60.33 1.65 2.77 3.91 5.54
2½ 65 73.03 2.11 3.05 5.16 7.01
3 80 88.90 2.11 3.05 5.49 7.62
4 100 114.30 2.11 3.05 6.02 8.56
6 150 168.28 2.77 3.40 7.11 10.97
8 200 219.08 2.77 3.76 8.18 12.70
10 250 273.05 3.40 4.19 9.27 12.70
12 300 323.85 3.96 4.57 9.52 12.70

Source: InfraBuild Pipe & Fittings Data Charts, page 18. Values retain the source’s rounding. Use the contractually specified standard edition for acceptance; other tables may round OD differently.

Stainless steel pipe schedule chart comparison: NPS 2 pipe ends in 10S, 40S and 80S

What do NPS, DN, OD and ID mean?

Read the size designation first, then check the physical dimensions.

NOMINAL SIZENPS 2 ↔ DN 50

Two designations for the same nominal pipe size

PHYSICAL OUTSIDE DIAMETER60.33 mm

The OD listed for this size in the reference chart

NPS

Nominal Pipe Size. Identifies the pipe size; it is not a measured inside diameter.

DN

Nominal metric designation. DN 50 corresponds to NPS 2 here; it does not mean a measured 50 mm bore.

OD

Outside Diameter. The dimension across the outside of the pipe. At the same NPS, it stays unchanged across the listed schedules.

ID

Inside Diameter. The bore inside the pipe. At the same OD, a thicker wall gives a smaller bore.

CALCULATE THE NOMINAL BOREID = OD − 2 × wall

Use consistent units.

NPS 2 · SCHEDULE 40S

60.33 − (2 × 3.91)

= 52.51 mmCalculated nominal inside diameter

Specify a controlled bore separately. NPS alone does not control ID. Actual dimensions and acceptance limits depend on the applicable product tolerances and purchase specification.

What does the S in 10S, 40S and 80S mean?

The S suffix identifies the stainless steel dimensional schedule series associated with ASME B36.19. Keep it in the purchase description. Do not silently replace 40S with 40 or assume every size has an identical wall under ASME B36.10.

Aalco’s ANSI pipe reference explains the suffix distinction. ASME’s B36.19-2022 publication information identifies the standard as Welded and Seamless Wrought Stainless Steel Pipe. State the edition required by the project.

How should you compare 10S, 40S and 80S?

Compare them at the same NPS. A higher schedule in these columns gives a thicker wall and smaller nominal bore. That changes flow area, material quantity and the pipe end that must be matched during fabrication.

Start from the engineer’s required wall, then check the dimensional series, connection details and procurement options. A thicker wall may add cost and weight without resolving a material compatibility problem. Grade selection and corrosion assessment remain separate decisions.

A schedule chart does not establish allowable working pressure. That assessment depends on the material, design temperature, governing piping code, wall tolerance, corrosion allowance, joint details and other design conditions. Obtain the approved specification before requesting substitutions.

Pipe size and tube size need different descriptions

Check whether the drawing calls for NPS pipe or tube specified by outside diameter and wall. A request for “2-inch stainless” leaves that unresolved. A nominal 2-inch pipe description cannot be exchanged for a 2-inch OD tube description without checking the drawing.

Include a dimensional sketch when the item must fit existing equipment. For fabrication details, see Jianglin’s stainless steel welding guide; the approved welding procedure and project specification still govern the work.

What should a stainless steel pipe RFQ include?

Give suppliers a complete line item so their offers can be compared against the same requirement.

RFQ field What to state
Material Exact grade and applicable product specification, including edition
Dimensions NPS, DN where useful, schedule with S suffix, dimensional standard and units
Manufacturing route Seamless or welded as required by the project
Supply condition Length, quantity, finish, end preparation and packaging
Quality requirements Permitted tolerances, required testing, material documents and traceability
Commercial details Delivery location, required date and permitted alternatives

A dimension-only example is “NPS 2, Schedule 40S, OD 60.33 mm × nominal wall 3.91 mm.” Add the material and quality requirements before using it as an order description.

What should you check when the pipe arrives?

Match the marking and documents to the purchase order. Confirm grade identification, size, schedule, manufacturing route and traceability as required by the contract.

Check OD, wall thickness, length and ends against the specified acceptance criteria using suitable measuring equipment. Nominal chart values are not upper or lower acceptance limits. Record discrepancies before cutting or welding the pipe.

Frequently asked questions

Is Schedule 40S a 40 mm wall?

No. It is a schedule designation. NPS 2 Schedule 40S has a nominal wall of 3.91 mm in this chart; other sizes have different walls.

Does the outside diameter change with schedule?

For a given NPS in the chart, OD stays the same across the listed schedules. Wall thickness and calculated bore change.

Can I replace 10S with 40S?

Ask the responsible engineer to approve the change. Check bore, weight, connections and fabrication requirements before accepting it.

Does this chart confirm Jianglin stock?

No. It is a dimensional reference. Availability and order conditions require confirmation for the exact specification.

Send a complete pipe specification for review

Send your grade, NPS, schedule, required standard, quantity and delivery destination through Jianglin’s contact page. Include the drawing and inspection requirements so the requested item can be assessed accurately.

About the Author

The Jianglin Steel editorial team writes purchasing guides for buyers and fabricators sourcing stainless steel. Its Knowledge Base covers material selection, ordering specifications and incoming inspection.

Leave a Comment

Your email address will not be published. Required fields are marked *

Share The Post Now:

Picture of Hey there, I’m Michael Li

Hey there, I’m Michael Li

I’m the Sales manager of Jianglin We provide high-quality stainless steel products to industries such as construction, automotive, aerospace, and manufacturing industries.
Have questions? Reach out to us, and we will provide you with a perfect solution.

Related Articles